مزود طاقة خطي عالية الطاقة عالية الجهد
أحصل على آخر سعرالدفع نوع: | T/T |
إنكوترم: | FOB,CFR,CIF,EXW |
أدني كمية الطلب: | 1 Piece/Pieces |
نقل: | Ocean,Land,Air,Express |
ميناء: | SHANGHAI,NANJING,QINGDAO |
الدفع نوع: | T/T |
إنكوترم: | FOB,CFR,CIF,EXW |
أدني كمية الطلب: | 1 Piece/Pieces |
نقل: | Ocean,Land,Air,Express |
ميناء: | SHANGHAI,NANJING,QINGDAO |
نموذج: HVLP
علامة تجارية: مثالي
مكان المنشأ: الصين
Input Voltage: Single Phase 220vac / Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Power Transformer Ac / Dc Conversion
Power Supply Type: Linear Ac / Dc Conversion
Working Mode: Constant Voltage / Constant Current
Display Mode: Digital Led
Control Mode: 10-Turn Potentometers
Protections: Ovp, Ocp, Otp And Short Circuit Protections
Applications: Lab / Education / Calibration / Electrostatic / Hipot / Component Test
Cooling: Forced Air Cooling
بيع الوحدات | : | Piece/Pieces |
نوع الحزمة | : | حالة الخشب الرقائقي |
مثال الصورة | : | |
تحميل | : |
HVLP عالي الطاقة مزود طاقة DC الجهد العالي
ملخص
HVLP Series Series Linear High Voltage Supplies هي إمدادات طاقة عالية الجهد تحقق تحويل AC/DC من خلال محولات تردد الطاقة والتحكم في حلقة الترانزستور. بالمقارنة مع تبديل إمدادات الطاقة عالية الجهد ، فإن إمدادات الطاقة الخطية عالية الجهد لديها ثبات أعلى ، ودقة أعلى ، وموجهة انخفاض الإخراج. والأهم من ذلك ، نظرًا لاستخدام مبدأ تحويل تردد الطاقة AC/DC ، لا يحتوي مصدر الطاقة الخطي العالي الجهد على تداخل إشعاعي عالي التردد ، وهو مناسب بشكل خاص للاستخدام في الأماكن مع القيود المفروضة على EMC و EMI.
تحتوي إمدادات طاقة HVLP HV HV على مجموعة واسعة من مواصفات الإخراج ، وتتراوح طاقة الخرج من 1 كيلو وات إلى 400 كيلو واط ، ويمكن أن يصل جهد الخرج إلى ما يصل إلى 50 كيلو فولتشر ، وقبول التخصيص.
تعتمد مزود الطاقة الخطي HV بالكامل من السلسلة على هيكل معدني من الدرجة الصناعية ، ومحول الجهد العالي متعدد الجهد النحوي النحوي ، ومرشحًا متعدد الموثوقات ، وضمان أن تعمل إمدادات الطاقة لفترة طويلة في وقت طويل في وقت طويل في وقت طويل. الحمل الكامل مع الاستقرار العالي ، والدقة العالية ، والخصائص الإلكترونية المنخفضة للغاية ، مزودة بدائرة حماية كاملة ، والتي يمكن أن تضمن بشكل أفضل موثوقية مصدر الطاقة الخطي نفسه وسلامة حمل العميل.
يمكن ضبط جهد الخرج والتيار بواسطة مقياس الجهد 10 دوران مع مقياس وقفل في المقدمة ، مجهز بـ 4 1/2 أرقام عالية الدقة في قراءة قيمة الإخراج ، ويمكن أيضًا إضافة واجهة اتصال RS لعملية التحكم عن بُعد السيطرة على ومراقبة HVPs الخطية.
سمات
ل أكثر من 200 نموذج ، جهد الخرج: 800V ~ 50kV ، إخراج الحالية: 0 ~ 500A ، طاقة الإخراج: 10KW-400KW.
ل وضع الجهد الثابت ووضع تيار ثابت ، قابلة للتبديل التلقائي ، الجهد الإخراج / التيار قابلة للتعديل باستمرار من 5 ٪ إلى 100 ٪ القيمة المقدرة.
ل حماية الجهد الإفراط في الجهد: قيمة الجهد الزائد قابلة للتعديل بشكل مستمر من 0 إلى 110 ٪ من القيمة المقدرة ، فإن التقلب التلقائي لأسفل عندما يتجاوز جهد الإخراج نقطة مجموعة الجهد الزائد.
ل الحماية القصيرة: صمدت الدائرة القصيرة تحت بدء التشغيل أو أي أوضاع عمل ، إنذار الصوت والضوء عندما يكون الإخراج قصيرًا. (<6kV)
ل تلقائيًا عندما تكون الدائرة القصيرة والصوت والإنذار الخفيف (> 6kV)
ل Over Load Protection: تلقائيًا عندما يكون لتوفير الطاقة أو الحمل خطأ ويتجاوز تيار الإخراج 1.5 مرة من القيمة المقدرة.
التطبيقات
ل المعاهد ، اختبارات HV الجامعية.
ل اختبار حرق مكون HV Electronics ، اختبار تفريغ الغاز.
ل Klystron ، أنبوب المغناطيس ، قيادة بندقية إلكترونية.
ل HV مكثف الشحن.
ل الحالات الأخرى تحتاج إلى إخراج HV.
Input |
Voltage |
Single-phase 220Vac±10% (≤3KW) Three-phase 380Vac±10% (>3KW) |
|
Frequency |
50Hz±10% |
||
Output |
Output modes |
DC C.C. / C.V. |
|
Rated power |
*** kW |
||
Output voltage adjusting range |
0V ~ *****V |
||
Output current adjusting range |
0A ~ ***A |
||
Output grounding mode |
(Grounding: two optional modes, default configuration is negative high-voltage, positive grounding) 1. Positive high-voltage, negative grounding 2. Negative high-voltage, positive grounding |
||
Accuracy (C.V.) |
Line regulation |
≤0.1% Of the rated value (output voltage change ratio under input ±10% change) |
|
Stability |
during 8 hrs≤0.3% of the rated value (output voltage change ratio due to 8 hours continuously working) |
||
Temp. coeff.offset |
≤0.04% of the rated value/℃(output voltage change ratio due to environment temperature changes) |
||
Load regulation |
≤0.3% of the rated value (output voltage change ratio due to output current change from 0 to rated value) |
||
Accuracy (C.C.) |
Line regulation |
≤0.1% Of the rated value (output current change ratio under input ±10% change) |
|
Stability |
during 8 hrs≤0.3% of the rated value(output current change ratio due to 8 hours continuously working) |
||
Temp. coeff.offset |
≤0.04% of the rated value/℃(output current change ratio due to environment temperature changes) |
||
Load regulation |
≤0.3% of the rated value (output current change ratio due to output voltage change from 0 to rated value) |
||
Ripple +noise (RMS) |
Positive high-voltage, negative grounding: ≤0.2% of the rated value+10mV (80%~100% rated output) Negative high-voltage, positive grounding: ≤0.1% of the rated value+10mV (80%~100% rated output) |
||
Efficiency |
≥75% (measured @ 80%-100% resistive loading) |
||
Working ability |
Withstand long-term continual working. |
||
Setting & Display |
Control mode |
10-turn Potentiometer (with-lock) |
|
Display mode |
41/2 Digital LED |
||
Display error |
Voltage |
≤±1%±1digit (range:5%~50% of the rated value) |
|
Current |
≤±0.5%±1digit (range:50%~100% of the rated value) |
||
Display resolution |
Voltage |
Four-digit display with a minimum resolution of 0.1V / 1V (As per rated output values) |
|
Current |
Four-digit display with a minimum resolution of 0.01A / 1mA (As per rated output values) |
||
Load characteristic |
On demand |
||
Protection & Monitoring functions |
Input protection |
Input lack voltage and lack phase protection. (available for three-phase input) |
|
Output over voltage protection (OVP) |
Power supply automatically cuts off output and alarms when output has over voltage. |
||
Output over current protection (OCP) |
Power supply automatically cuts off output and alarms when the output has over current. |
||
Over temperature protection (OTP) |
Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds 85 °C. |
||
Output short-circuit protection |
Power supply automatically cuts off output and alarms when power supply output has short-circuited. |
||
Noise |
≤65 ~ 75dB |
||
Protection degree |
IP20 |
||
Cooling method |
Forced air cooling |
||
Working conditions |
Ambient temperature |
-10℃~40℃ |
|
Humidity |
10%~80%(non-condensing) |
||
Height |
≤1000m |
||
Accessories |
Fuse * 1 set High-voltage output line * 1pc Operation manual * 1pc |
||
l Input Voltage: Power source voltage can be changed to others on request. l Custom-made specifications are on request. |
|||
|
ل إنذار قصير: إنذار الصوت والضوء عند إخراج الدوائر القصيرة.
ل Off-Off-Off-Load و Discrading: عند إيقاف تشغيل إمدادات الطاقة ، سيتم تقطيع إمدادات الطاقة تلقائيًا من الحمل والتصريف الكهربائي في الحمل من أجل السلامة.
ل شاشة الإخراج: الجهد والتيار كلاهما عرض رقمي LED.
ل العمل النابض: يمكن أن يضيف وحدة تحكم الوقت لتكون مزود الطاقة النابض.
ل منفذ الاتصال: RS232/RS485 للتواصل مع الكمبيوتر ليتم التحكم فيه عن بُعد ومراقبته بواسطة أجهزة الكمبيوتر.
ل الإشارة التناظرية: 0 ~ 5V (10V) أو 4 ~ 20ma إشارة تمثيلية لجهد الخرج والتحكم الحالي.Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.